Pyther Innovation
JSON Stored00:00:00 UKDEMO
AM
Total Devices
20
configured
Online
18/20
connected
Active Relays
3
energised
Unread Alarms
1
check notifications
Schedules
4
enabled
Customer Sensor Status Standard (6 Colours)
Offlinegrey
2sensors
Sensor is disconnected or offline
Outside Schedulepale orange
3sensors
Sensor online but outside scheduled hours
No Measurementpale blue
3sensors
Sensor online, inside scheduled hours, not yet generated a measurement
In-Rangepale green
6sensors
Sensor online, inside scheduled hours, object in-range measurement obtained
Wait Statepale red
3sensors
Sensor online, inside scheduled hours, in “Wait” state, ie: object left / measurement no longer in-range
Alarmred
3sensors
Sensor online, inside scheduled hours, in “Alarm” state
Alarm Cascade Flow
NVR Alarm Output
Closing Contact IN1 (Black connector)
OPEN — NORMAL→
LAN Relay 1 (Parent Controller)Online
192.168.1.101:6722 · LAN/PoE
⚡ Own Relay: FloodlightSTANDBY
Parent triggers own relay in response to closing contact
→
Tractor Shed 1 Bay 1 Sensor → Floodlight
192.168.1.102 (TCP 6722)
Online
Tractor Shed 2 Bay 1 Sensor → Siren
192.168.1.103 (TCP 6722)
Online
Tractor Shed 2 Bay 2 Sensor → Aux Relay
192.168.2.104 (TCP 6722)
Online
Device Status
| Device & Unit | Location | Sensor Status | Role | Status | Relay | |
|---|---|---|---|---|---|---|
LAN Relay 1 (Parent Controller)Controller 192.168.1.101 | Elm Tree Farm Tractor Shed 1 | In-Range 1.8 m (In-Range) | Parent | Online | standby | |
Tractor Shed 1 Bay 1 SensorBay 1 192.168.1.102 | Elm Tree Farm Tractor Shed 1 | In-Range 1.8 m (Tractor Parked) | Child | Online | standby | |
Tractor Shed 2 Bay 1 SensorBay 1 192.168.1.103 | Elm Tree Farm Tractor Shed 2 | Wait State Object Left (Wait 45s) | Child | Online | standby | |
Tractor Shed 2 Bay 2 SensorBay 2 192.168.2.104 | Elm Tree Farm Tractor Shed 2 | Outside Schedule Standby (Out of Hours) | Child | Online | standby | |
Tractor Shed 1 Bay 1 SensorBay 1 192.168.1.115 | Riverside Farm Tractor Shed 1 | Alarm ALARM (Threshold < 0.5m) | Standalone | Online | 15s | |
Tractor Shed 1 Bay 2 SensorBay 2 192.168.1.116 | Riverside Farm Tractor Shed 1 | No Measurement No measurement yet | Standalone | Online | standby | |
Tractor Shed 1 Bay 3 SensorBay 3 192.168.1.117 | Riverside Farm Tractor Shed 1 | Offline Disconnected | Standalone | Offline | standby | |
Machine Shed 1 Bay 1 SensorBay 1 192.168.1.118 | Riverside Farm Machine Shed 1 | In-Range 2.3 m (Harvester Present) | Standalone | Online | standby | |
North Building Room 1 SensorRoom 1 10.0.1.11 | First Retirement Home & Residential Hospice North Building | In-Range Bed Occupied (0.4 m) | Standalone | Online | standby | |
North Building Room 2 SensorRoom 2 10.0.1.12 | First Retirement Home & Residential Hospice North Building | Wait State Resident Out of Bed (Wait 12m) | Standalone | Online | standby | |
North Building Room 20 SensorRoom 20 10.0.1.20 | First Retirement Home & Residential Hospice North Building | Alarm FALL ALARM (> 15m unreturned) | Standalone | Online | 30s | |
South Building Room 1 SensorRoom 1 10.0.2.11 | First Retirement Home & Residential Hospice South Building | No Measurement No measurement yet | Standalone | Online | standby | |
South Building Room 2 SensorRoom 2 10.0.2.12 | First Retirement Home & Residential Hospice South Building | Outside Schedule Standby (Night Monitor) | Standalone | Online | standby | |
South Building Room 30 SensorRoom 30 10.0.2.30 | First Retirement Home & Residential Hospice South Building | Offline Disconnected | Standalone | Offline | standby | |
North Building Room 1 SensorRoom 1 10.1.1.11 | Second Retirement Home & Residential Hospice North Building | In-Range Resident Present (0.5 m) | Standalone | Online | standby | |
North Building Room 2 SensorRoom 2 10.1.1.12 | Second Retirement Home & Residential Hospice North Building | No Measurement Calibrating | Standalone | Online | standby | |
North Building Room 20 SensorRoom 20 10.1.1.20 | Second Retirement Home & Residential Hospice North Building | Wait State Wait State (Object Left) | Standalone | Online | standby | |
South Building Room 1 SensorRoom 1 10.1.2.11 | Second Retirement Home & Residential Hospice South Building | Outside Schedule Outside Scheduled Hours | Standalone | Online | standby | |
South Building Room 2 SensorRoom 2 10.1.2.12 | Second Retirement Home & Residential Hospice South Building | In-Range In-Range (0.6 m) | Standalone | Online | standby | |
South Building Room 30 SensorRoom 30 10.1.2.30 | Second Retirement Home & Residential Hospice South Building | Alarm CALL ALARM (Triggered) | Standalone | Online | 20s |
Recent Activity
Physical Input Triggered11:25:00 (UK)
Farm NVR Alarm contact closed on IN1 (black connector)
Physical Input Success
Parent Relay Activated11:25:00 (UK)
Parent triggered own relay: Floodlight (5s)
Local Relay Success
TCP Command Sent11:25:01 (UK)
Command 'RELAY:SET:ON:20' -> 192.168.1.102:6722
TCP Listener Success
Floodlight Relay Activated11:25:01 (UK)
LAN Relay 2 Floodlight turned ON for 20s
TCP Listener Success
Siren Activated11:25:01 (UK)
LAN Relay 3 Siren turned ON for 5s
TCP Listener Success
Scheduled Action06:00:00 (UK)
LAN Relay 2 Floodlight switched OFF
Schedule Success